Abstract
The Load Current Multiplier concept (LCM) was validated for the first time on a high-voltage nanosecond pulse-power generator. The designed new device allowed to increase the load current from the nominal 0.8-0.9 MA up to 1.6 MA in static loads with constant inductance and up to 1.4 MA in a planar wire-array plasma loads. These results were achieved without modifying the generator energetic or architecture. LCM allowed both the load magnetic energy increase and the increase of soft X-ray radiation from z-pinch plasmas.