Abstract
Conference Title: 2017 2nd International Conference on Electrical & Electronic Engineering (ICEEE) Conference Start Date: 2017, Dec. 27 Conference End Date: 2017, Dec. 29 Conference Location: Rajshahi, Bangladesh In this research work, an experimental analysis has been done with a liquid based thermoelectric electronic cooling system, using two developed aluminium heat exchangers. An Ethylene-Glycol based fluid was used as the coolant in the cooling system. A modified cooling module was used for the proposed electronic cooling system. Both numerical analysis using COMSOL Multiphysics and experimental work were performed to investigate a better heat exchanger for the system. It is found that the large aluminium heat exchanger shows better performance compared to the small one. The commercially found cooling system performed the worst performance. The temperature variation was between 29–30 °C, which is nearly 2 °C less than the commercial cooling system and showed steady performance.