DC IR-Drop Analysis of Power Distribution Networks by a Robin Transmission Condition-Enhanced Discontinuous Galerkin Method
Journal article   Peer reviewed

DC IR-Drop Analysis of Power Distribution Networks by a Robin Transmission Condition-Enhanced Discontinuous Galerkin Method

An Fa Yang, Min Tang, Jun Fa Mao, Li Jun Jiang, Hakan Bagcii, Ping Li and Hakan Bagci
IEEE transactions on components, packaging, and manufacturing technology (2011), Vol.12(1), pp.89-99
01/2022

Abstract

DC IR-drop discontinuous Galerkin~(DG) method domain decomposition method (DDM) Electric potential electrical–thermal cosimulation Electrostatics Finite element analysis Mathematical models Robin transmission condition (RTC) Steady-state Thermal analysis Thermal decomposition