Abstract
The current study investigates the effects of coke particle characteristics and paste formulation on the flowability and the compression behavior of anode pastes. Shape factor and texture of different fractions of cokes were characterized using an image analysis system where the characteristics of each coke were correlated to its vibrated bulk density (VBD). A compression test was designed to study the effects of particle characteristics and paste recipe on the compactability of pastes. The test was applied on four anode pastes, prepared from different coke types, particle size distributions and pitch contents. It was observed that the compression test is significantly sensitive to any changes in raw materials characteristics and formulations. Consequently, the compression test may be used as a tool for evaluating anode quality in relation with material variations.