Abstract
An 18-year-old pregnant woman with severe pulmonary valve stenosis and exertional dyspnea underwent balloon dilation during pregnancy using sole echocardiographic guidance to protect the baby from radiation. The main technical difficulty encountered was during advancement of the catheter across the right ventricular outflow tract into the pulmonary valve. This was overcome using a wedge balloon catheter over a percutaneous transluminal coronary angioplasty (PTCA) wire. Using echo guidance, the balloon was positioned across the pulmonary valve and inflated. Pulmonary balloon valvuloplasty can be performed safely using sole transthoracic echocardiography guidance without fluoroscopy.
Une femme enceinte de 18 ans souffrant d’une sténose pulmonaire sévère et d’une dyspnée d’effort a subi une dilatation par ballon sous guidage échocardiographique seul afin de protéger le bébé de la radiation. La principale difficulté technique a été rencontrée durant la progression du cathéter à travers la chambre de chasse du ventricule droit dans la valve pulmonaire et a été surmontée à l’aide d’un cathéter biseauté à ballon sur un guide pour angioplastie coronarienne (AC). Sous échoguidage, le ballonnet a été placé dans l’orifice de la valve pulmonaire et gonflé. La valvuloplastie pulmonaire par ballon peut être réalisée en toute sécurité sous guidage par échocardiographie transthoracique sans fluoroscopie.