Abstract
An easy method of tuning the response of maximum magnetoimpedance (MI) ratio in Fe75.5Si13.5B7Nb3Cu1 amorphous ribbons was investigated by laser ablation. In order to obtain different GMI peak positions, the stripes were ablated by laser with different separations on the surface layer of the ribbon. When the stripes were parallel (or perpendicular) to the applied magnetic field, the peak location of maximum MI ratio would drift to larger (or smaller) external field. And the shift was correlated with the spaces between stripes. The applied fields corresponding to the minimum and maximum values of peak location are 13 Oe and 49 Oe at the frequency of 15 MHz, respectively. The phenomenon can be explained by the anisotropy field induced by demagnetizing field after the laser ablation. (C) 2012 Elsevier B.V. All rights reserved.